ef8c0feb91
Wires the burst_mode flag through QtScanController to ScanEngine and adds a checkbox to the scan panel. The setting persists via ScanDefaults like the other scan fields, defaulting to off — per-row acquisition stays the default path until burst mode has run on the rig and the gate-off preflight has settled which TRIGOUT value idles the pin low. scan_format.md — the acquisition settings table had drifted from the code it claimed to describe: it attributed the settings to sc3_aui_app.py (they moved to core/scope_sras.py in the Phase 2 extraction), listed a 1.24 V trigger level and 0 % offset where the code sets 0.500 V and HORizontal:POSition 30, and did not mention the logic-AND scan trigger at all. Corrected, pointed at the module that actually owns them, and noted that none of it affects byte layout — only where the acoustic packet lands inside a frame. Added an acquisition-paths section: the two paths write byte-identical files and the choice is a runtime flag that is not recorded in the file, so a reader never needs to care which produced it. Documents where row boundaries come from in a burst and that either path squares rows up to n_frames. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>